Consumer unit upgrades: what is involved
By Liam, OHMS GROUP LTD ·
The consumer unit, often still called the fuse box, is where every circuit in the house is protected. Replacing an old one is one of the most worthwhile electrical jobs in an older home, mainly because modern boards add RCD protection, which disconnects the supply very quickly if current leaks to earth, such as through a person.
Here is what an upgrade involves, the choices you will be asked to make, and what you should get at the end.
Why people replace their consumer unit
- An old board with rewireable fuses and no RCD protection
- An EICR that recommended an upgrade, or found faults at the board
- A rewire, extension or new circuit that needs a modern board
- Plastic boards in poor condition or with signs of overheating
- Nuisance tripping that takes out half the house at once
RCD boards and RCBO boards
There are two common layouts. A split load board has two or more RCDs, each protecting a group of circuits through ordinary circuit breakers. It works, but one fault trips every circuit on that side of the board, which might be the fridge, the freezer and half the lights.
An RCBO board gives each circuit its own combined breaker and RCD. A fault on the kitchen sockets then trips only the kitchen sockets. RCBO boards cost more because each device costs more, but for most homes they are the better long-term choice.
Testing comes first
A new board will not hide problems in the wiring behind it. In fact, RCD protection often exposes existing faults, such as a neutral and earth touching somewhere, that an old fuse board never noticed. That is why a good electrician tests the existing circuits before fitting the new board, and tells you about any faults so they can be fixed as part of the job.
If you already have a recent EICR, share it. It saves time and shows what needs attention.
Earthing and bonding
Many older homes have undersized or missing main protective bonding to the incoming gas and water pipes. This is normally brought up to standard as part of a board change, because the new board relies on a sound earthing arrangement to protect you.
Surge protection and arc fault detection
Since the 2022 amendment, BS 7671 expects surge protection devices to be fitted in almost all new work. In limited cases the owner can choose not to have one, but not where a safety service such as mains smoke alarms is fed from the board, which covers most homes. Your electrician will explain what applies to yours.
Arc fault detection devices, or AFDDs, detect the kind of arcing that comes from damaged cables and loose connections. Since the 2022 amendment to BS 7671 they are required on socket circuits up to 32A in certain buildings, including houses in multiple occupation and care homes, and recommended elsewhere. In an ordinary house they are an option rather than a requirement.
What happens on the day
- The power is isolated and the existing circuits are tested.
- The old board is removed and the new one fitted. BS 7671 requires a non-combustible enclosure in homes, which in practice usually means metal.
- Circuits are connected, labelled and tested again with the new protection in place.
- Power is restored and the electrician shows you how the board works and how to test the RCDs.
Expect to be without power for most of a working day. If you work from home or have medical equipment, mention it at the survey.
Certificates and Part P
Replacing a consumer unit is notifiable work under Part P of the Building Regulations in England. You should receive an Electrical Installation Certificate with the test results, and a Building Regulations compliance certificate either through the electrician's competent person scheme or from building control. Keep them with your house documents, as buyers' solicitors and insurers may ask for them.
Consumer unit upgrades in Kent
We fit metal-clad RCBO boards with labelled circuits, bring earthing and bonding up to standard and test before and after. Read more about our consumer unit and rewiring service, or start with an EICR inspection if you are not sure what you need. We are based in Aylesford and work across Sevenoaks and the rest of west Kent. Call 01622 278762 for a free survey and fixed written quote.
Common questions
Is an RCBO board worth the extra cost?
For most homes, yes. Each circuit has its own protection, so one fault trips one circuit rather than half the house.
How long does a consumer unit change take?
Usually most of a working day with the power off, longer if faults are found in testing or bonding needs upgrading.
Do I need a certificate for a new consumer unit?
Yes. It is notifiable under Part P. You should get an Electrical Installation Certificate and a Building Regulations compliance certificate.