Fire alarm categories explained: which does your business need?

By Liam, OHMS GROUP LTD ·

The fire alarm category your business needs is set by your fire risk assessment, using the categories in BS 5839-1: M for manual systems, L1 to L5 for protecting people, and P1 or P2 for protecting the building and its contents. The right one depends on how the premises are used, who is in them, and how quickly a fire would be noticed.

This guide explains each category in plain English, who decides, and what you need to keep the system compliant once it is in.

Who decides which category you need

In England and Wales the Regulatory Reform (Fire Safety) Order 2005 puts the duty on the responsible person, usually the employer, owner or managing agent. They must carry out a fire risk assessment and provide suitable fire detection and warning. The assessment is where the category comes from. Your insurer may add its own requirements for property protection, and new buildings or major alterations also have to satisfy Building Regulations.

A good installer will read your fire risk assessment, survey the building and specify a category that matches it. If you do not have a current assessment, get that done first.

Category M: manual systems

A category M system has manual call points and sounders, with no automatic detection. It relies on someone finding the fire and raising the alarm. It can suit small premises that are always occupied while open, where a fire would be seen quickly. Most L and P systems include manual call points as well.

Categories L1 to L5: protecting life

L categories add automatic detection so people get warned in time to escape. The number tells you how much of the building is covered:

  • L1: detection throughout the building. The highest level of life protection.
  • L2: everything in L3, plus detection in specified rooms with a higher fire risk, such as kitchens or plant rooms.
  • L3: detection on escape routes and in rooms that open onto them, so a fire is picked up before it cuts off the way out.
  • L4: detection within the escape routes only, such as corridors and stairs.
  • L5: a bespoke system designed around one specific risk identified in the assessment.

Buildings where people sleep, such as hotels, care settings and blocks of flats with communal systems, generally need a higher level of cover than an office used in the daytime.

Categories P1 and P2: protecting property

P categories are about limiting damage and getting the fire service there sooner, so they are often driven by insurers and by the value of what is inside:

  • P1: automatic detection throughout the building.
  • P2: detection only in defined areas, such as a server room, stock store or high risk process.

A system can be specified to meet both, for example L2 for life safety with P2 cover for a valuable area.

Choosing the right detectors

The category says where detection goes. The detector type is a separate choice. Smoke detectors in a kitchen cause false alarms, so heat detection is often used there. Warehouses with high ceilings may need optical beam detectors rather than point detectors. Getting this right is what keeps a system reliable instead of something people learn to ignore.

You will also hear about conventional and addressable panels. A conventional panel tells you which zone has gone into alarm. An addressable panel identifies the exact device, which makes larger buildings much quicker to search and fault find.

After installation: testing and servicing

BS 5839-1 expects a system to be looked after, not just fitted. In practice that means:

  • A weekly test by the user, operating a different manual call point each week and recording it in the logbook
  • Inspection and servicing by a competent person at intervals of no more than six months
  • Faults and false alarms recorded and dealt with promptly
  • Certificates kept for design, installation, commissioning and servicing

If your fire risk assessor or the fire service visits, the logbook and certificates are the evidence they will ask to see.

How we can help

OHMS GROUP LTD is on the BAFE Fire Safety Register (ID 302582) and designs, installs, commissions and maintains BS 5839 systems for offices, warehouses, shops, restaurants and residential blocks. See our fire alarm installation and maintenance service, or our pages for Tonbridge, Maidstone and London. Call 01622 278762 for a free site survey and quote.

Common questions

What is the difference between L1 and L2 fire alarms?

L1 has automatic detection throughout the building. L2 covers escape routes and the rooms opening onto them, plus specified higher risk rooms.

Who decides which fire alarm category a building needs?

The responsible person, based on the fire risk assessment required by the Regulatory Reform (Fire Safety) Order 2005. Insurers may add property protection requirements.

How often should a commercial fire alarm be serviced?

BS 5839-1 recommends inspection and servicing by a competent person at least every six months, with a weekly user test of a manual call point.